Quality
— EACCertified products
Vargov®Design products are serially certified in the Eurasian Economic Union: EAEU certificates of conformity cover more than 300 LC lighting compositions.
EAC conformity mark
The single conformity mark for products circulating on the Eurasian Economic Union market
300+
LC pieces covered by the certificates
2
serial EAEU certificates of conformity
8
GOST testing standards
2031
certificates valid until 31.05.2031
Serial EAEU certificatesof conformity
Vargov lighting compositions are certified as serial production — the certificate covers every unit of the listed LC pieces, not a single batch. Certificates are valid from 01.06.2026 to 31.05.2031.
Certificate No. 10095925
- TR CU 004/2011 “On the safety of low-voltage equipment”
- TR CU 020/2011 “Electromagnetic compatibility of technical devices”
53+ LC pieces · serial production
Certificate No. 10095927
- TR CU 004/2011 “On the safety of low-voltage equipment”
250+ LC pieces · serial production
Certification body — Test-St. Petersburg LLC, accreditation certificate ROSS RU.0001.10SP28. Certification scheme 1s · serial production. Full certificate texts and annexes listing the LC codes are available on request for tender and project documentation.
Declarationsof conformity
TR EAEU 037/2016 “On the restriction of hazardous substances in electrical and electronic products”. The restriction of hazardous substances is what the rest of the world knows as RoHS: lead, mercury, cadmium and other compounds in electrical equipment. Registered 29.08.2026, valid until 27.08.2031.
ЕАЭС N RU Д-CN.РА07.В.71518/26
Test report 08-2026СИ.04-4476
53 LC pieces · serial production
ЕАЭС N RU Д-CN.РА07.В.71557/26
Test report 08-2026СИ.04-4477
266 LC pieces · serial production
Testing laboratory ABK-Sistema Centre for Expertise and Quality, Aleksandrov. Declaration scheme 1d · serial production. 310 LC pieces · Vargov LED lighting compositions. The entries are open in the Rosaccreditation register and can be verified by the declaration number.
What this meansin practice
A declaration of conformity to TR EAEU 037/2016 confirms what the product is made of: no lead, mercury, cadmium, hexavalent chromium or brominated flame retardants above the permitted fractions. Elsewhere this requirement is known as RoHS.
Certificates and declarations answer for different things, and one does not replace the other. The TR CU 004/2011 and 020/2011 certificates say a luminaire is safe in operation: it will not give a shock, it will not interfere. The 037/2016 declaration says it is safe by composition, including at disposal. A project document set needs both.
Why this is not a formality
The declaration is issued for serial production, not for a batch: it covers every unit of the listed pieces, however many are made and whenever. A batch document would have to be obtained again for each delivery — and at handover it would turn out that what arrived is not covered by it.
The testing was real: samples were taken in May 2026, an accredited laboratory ran the tests, and the reports are named in the declarations themselves. The entries are open in the Rosaccreditation register — anyone can look them up by number, including your lawyer and your client.
What it gives the client
In a tender the document set is accepted without correspondence: there is a registration number, a validity period and a list of pieces you can point a finger at.
At handover built-in lighting equipment requires proof of conformity. Without documents the luminaire either comes down or the site is not accepted — and the composition is already mounted under a two-storey ceiling.
In a dispute liability for safety rests with whoever holds the documents. If nobody holds them, it rests with whoever installed the fitting.
Vetting a supplier
Three questions worth asking any supplier of bespoke lighting
- 1Is the document for a series or for a batch? A batch document does not cover the next delivery.
- 2Is your piece named individually? The wording “representative sample” means something else was tested.
- 3Is there a number in the accreditation register? A document that cannot be checked online does not exist.
For us the answer to all three is yes, and you can verify it without asking us.
Standards
Tested to GOST
Conformity with the technical regulations is confirmed by testing to the national GOST standards.
GOST IEC 60598-1-2017
Luminaires. General requirements and test methods
GOST IEC 60598-2-1-2011
Fixed general-purpose luminaires
GOST IEC 62471-2013
Photobiological safety of lamps and lamp systems
GOST IEC 62493-2014
Assessment of lighting equipment related to human exposure to electromagnetic fields
GOST IEC 61547-2013
EMC. Immunity requirements for lighting equipment
GOST CISPR 15-2014
Radio disturbance limits for lighting equipment
GOST IEC 61000-3-2-2017
EMC. Limits for harmonic current emissions
GOST IEC 61000-3-3-2015
EMC. Limitation of voltage fluctuations and flicker
Documents
Certificates — for your project
We will send the certificates of conformity and the annexes with LC codes for tender documentation and working drawings.